Report of RILEM TC 267-TRM phase 2: optimization and testing of the robustness of the R3 reactivity tests for supplementary cementitious materials - INSA Toulouse - Institut National des Sciences Appliquées de Toulouse Accéder directement au contenu
Article Dans Une Revue Materials and structures Année : 2022

Report of RILEM TC 267-TRM phase 2: optimization and testing of the robustness of the R3 reactivity tests for supplementary cementitious materials

Mohsen Ben Haha
  • Fonction : Auteur
Susan Bernal
  • Fonction : Auteur
Shashank Bishnoi
  • Fonction : Auteur
Özlem Cizer
  • Fonction : Auteur
Sabina Dolenec
  • Fonction : Auteur
Pawel Durdzinski
  • Fonction : Auteur
Johannes Haufe
  • Fonction : Auteur
Doug Hooton
  • Fonction : Auteur
Maria Juenger
  • Fonction : Auteur
Diana Londono-Zuluaga
  • Fonction : Auteur
Alastair Marsh
  • Fonction : Auteur
Milena Marroccoli
  • Fonction : Auteur
Marusa Mrak
  • Fonction : Auteur
Anuj Parashar
  • Fonction : Auteur
Cédric Patapy
Malene Pedersen
  • Fonction : Auteur
John Provis
  • Fonction : Auteur
Serge Sabio
  • Fonction : Auteur
Simone Schulze
  • Fonction : Auteur
Ruben Snellings
  • Fonction : Auteur
Antonio Telesca
  • Fonction : Auteur
Michael Thomas
  • Fonction : Auteur
Felipe Vargas
  • Fonction : Auteur
Anya Vollpracht
  • Fonction : Auteur
Brant Walkley
  • Fonction : Auteur
Frank Winnefeld
  • Fonction : Auteur

Résumé

Abstract The results of phase 1 of an interlaboratory test, coordinated by the RILEM TC 267-TRM “Tests for Reactivity of Supplementary Cementitious Materials” showed that the R 3 (rapid, relevant, reliable) test method, by measurement of heat release or bound water, provided the most reliable and relevant determination of the chemical reactivity of supplementary cementitious materials (SCMs), compared to other test methods. The phase 2 work, described in this paper aimed to improve the robustness of the test procedure and to develop precision statements for the consolidated test procedure. The effect of the pre-mixing and mixing conditions, and the impact of the mix design on the test method robustness were assessed and fixed for optimal conditions to carry out the R 3 heat release test. The effect of the drying step was evaluated to define the R 3 bound water test procedure in more detail. Finally, the robustness of the consolidated final test methods was determined by an interlaboratory study to define the precision statements.

Domaines

Génie civil
Fichier principal
Vignette du fichier
s11527-022-01928-6.pdf (1.06 Mo) Télécharger le fichier
Origine : Publication financée par une institution

Dates et versions

hal-03653047 , version 1 (20-01-2023)

Licence

Paternité

Identifiants

Citer

François Avet, Xuerun Li, Mohsen Ben Haha, Susan Bernal, Shashank Bishnoi, et al.. Report of RILEM TC 267-TRM phase 2: optimization and testing of the robustness of the R3 reactivity tests for supplementary cementitious materials. Materials and structures, 2022, 55 (3), pp.92. ⟨10.1617/s11527-022-01928-6⟩. ⟨hal-03653047⟩
64 Consultations
30 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More